This guide applies to the following models with 600/700/750 CFM silver metal blowers:
- Twister
- Q5
- Q2
- Q1
Tools Required
- Long Philips screwdriver
Follow the steps below to adjust and tighten an impeller
- Access the duct opening by either opening your cabinet (for inserts) or removing the stainless duct covers (wall mount)
- Unscrew the duct transition piece in order to shift the ducting to the side
- Look inside the blower casing to view the impeller and make the adjustment
How to adjust the impeller
Please review the video at this link for assistance on shifting the impeller if needed and tightening the set screw.
Motor still not working after impeller adjustment
If your blower/motor is still not functioning as expected after adjusting the impeller, replacement parts can be requested under warranty. These models include a lifetime blower warranty and 5 year parts warranty.